ChemGrout - manufactures high quality grouting equipment (mixers, pumps, accessories, and repair parts) at a fair price with outstanding customer service.
"Mfg. Grout Pumps, Grout Mixers, Largest Selection of Grouting Equipment in the World"

Paddle Mixer & Grout Pump    Colloidal Grouting Equipment    Grout Pumps    Mixers & Agitators    Select by Industry    Specialty Grout Plants    Home
 
ChemGrout grout pump and mixer test results for:
 
BASF Building Systems (Masterbuilders, Inc) Phone: 800-433-9517
889 Valley Park Drive Fax: 800-496-6067
Shakopee, MN 55379 Email: Customer Service
 
Material 
Application
Test Results
Max. Distance
Min. Pump
Shotpatch 21 Repair Mortar-Spray Applied
5 out of 10
50 ft
CG2TJ6
Shotpatch 21F Repair Mortar-Spray Applied
5 out of 10
50 ft
CG2TJ6
Emaco R-350 Repair Mortar
6 out of 10
75 ft
CG2TJ6
Emaco S77 CL Repair Mortar-Corrosion Inhibitor
5 out of 10
50 ft
CG2TJ6
Emaco S88 CI Repair Mortar-Spray Applied-Corrosion inhibitor
5 out of 10
25 ft
CG2TJ6
Emaco S88 CA Repair Mortar-Spray Applied
5 out of 10
50 ft
CG2TJ6
Emaco T-430 Repair Mortar
7 out of 10
150 ft
CG050
Embeco 885 Non-shrink Grout - Metallic
7 out of 10
150 ft
CG050
LA Repair Mortar Repair Mortar-Spray Applied
5 out of 10
50 ft
CG2TJ6
Masterbuilders 648 CP+ Epoxy grout - High Flow
5 out of 10
50 ft
CG050H
Masterflow 928 Non-Shrink Grout-Non-Metallic
7 out of 10
150 ft
CG050
Masterflow 1205 High Performance Grout for Highly Stressed Steel
9 out of 10
250 ft
CG600
Masterflow 1341 Universal Post-Tensioning Grout
9 out of 10
250 ft
CG600
Mastertop 112 Self Leveling-Polymer Modified
7 out of 10
150 ft
CG050
Set 45 Repair Mortar-Anchoring Cement
6 out of 10
75 ft
CG2TJ6
SP 20 Spray Mortar Repair Mortar - Microsilica, Fiber
5 out of 10
50 ft
CG2TJ6
Thoro Self-Leveling Self Leveling Underlayment
8 out of 10
150 ft
CG2C4
 
General Comments:
Grout mixing and pump test results were performed at ChemGrout using a specially instrumented size 6 progressing cavity grout pump.  The batches were mixed using the manufactures recommended mix ratios or the midpoint if a range was specified.   We are listing the minimal pump for the material.   The production rate required determines the correct mixer and pump size for a specific application.

Chart Key:
Manufacturer - The material manufacture, click to go to the manufacturer's web site.
Material - The manufacture's name for the material tested.
Application - The primary application specified by the manufacture for the material.
Test Results - The ChemGrout Pumpability Index®, click for detailed pump test results (need Adobe Acrobat).
Max. Distance - The maximum pumping distance as indicated by discharge pressure during testing.
Min. Pump - The minimum pump recommended by ChemGrout, see Pump Rating for details.


 