ChemGrout® grout pump and mixer test results for:
 
Repair Mortar, Spray Applied, Vertical & Overhead
 
Manufacturer
Material 
Test Results
Max. Distance
Min. Pump
ChemRex-Masterbuilders, Inc Shotpatch 21
5 out of 10
50 feet
CG2TJ6
ChemRex-Masterbuilders, Inc Shotpatch 21F
5 out of 10
50 feet
 CG2TJ6
ChemRex-Masterbuilders, Inc Emaco S88 CI
5 out of 10
25 feet
 CG2TJ6
ChemRex-Masterbuilders, Inc Emaco S88 CA
5 out of 10
50 feet
 CG2TJ6
ChemRex-Masterbuilders, Inc LA Repair Mortar
5 out of 10
50 feet
 CG2TJ6
Fox Industries Inc. FX-262
5 out of 10
75 feet
CG2TJ6
General Polymers, Inc. 1510 Permalith CE
7 out of 10
150 feet
CG2C6
General Polymers, Inc. 1507 Permalith CE-V
7 out of 10
150 feet
CG2C6
Lafarge Calcuim Aluminates, Inc. Sewpercoat - pumpable grade
5 out of 10
75 feet
CG2C6
MAPEI Planicem 53
6 out of 10
100 feet
CG030
MAPEI Planiseal 88
8 out of 10
200 feet
CG030
MAPEI Planitop 12
5 out of 10
75 feet
CG030
Quadex, Inc. QM-1s Restore
5 out of 10
75 feet
CG2C6
Quadex, Inc. Aluminaliner PF
5 out of 10
75 feet
CG2C6
Sika Corporation SikaCem 103
3 out of 10
12.5 feet
CG3L8
Sika Corporation SikaCem 133
3 out of 10
--
--
Sika Corporation Sika Repair 222 Plus
7 out of 10
75 feet
CG2TJ6
Sika Corporation Sika Repair 224
6 out of 10
50 feet
CG2TJ6
Sika Corporation Sika Repair SHB
5 out of 10
25 feet
CG030
Tamms Speed Crete PM
5 out of 10
50 feet
CG2C6
 
General Comments:
Grout mixing and pump test results were performed at ChemGrout using a specially instrumented size 6 progressing cavity grout pump.  The batches were mixed using the manufactures recommended mix ratios or the midpoint if a range was specified.   We are listing the minimal pump for the material.   The production rate required determines the correct mixer and pump size for a specific application.

Chart Key:
Manufacturer - The material manufacture, click to go to the manufacturer's web site.
Material - The manufacture's name for the material tested.
Application - The primary application specified by the manufacture for the material.
Test Results - The ChemGrout Pumpability Index®, click for detailed pump test results (need Adobe Acrobat).
Max. Distance - The maximum pumping distance as indicated by discharge pressure during testing.
Min. Pump - The minimum pump recommended by ChemGrout, see Pump Rating for details.


 